ระบบบ่มแก๊ซ คาร์บอนไดซ์ ชนิด Silver Line
A gas mixer for long-term live cell imaging applications with precise, active humidity control and CO2 regulation
- Preventing evaporation: constant, very high relative humidity level inside the stage top incubator due to patented, feedback-controlled humidity regulation
- Fully compatible with the ibidi Heating Systems
- For long-term physiologic conditions on the microscope with precisely controlled temperature, humidity, and CO2, ibidi offers Stage Top Incubators, which combine the ibidi Heating System and the ibidi Gas Incubation System
System includes:
Applications
The ibidi Gas Incubation System is ideal for live cell imaging experiments that require physiologic conditions on the microscope.
Combined with the ibidi Heating System, it serves as a complete Stage Top Incubator, precisely controlling essential parameters such as temperature, humidity, and CO2 levels on the microscope to get reproducible results of, for example:
- Chemotaxis assays
- Angiogenesis assays
- Cell migration assays
- Wound healing assays
- Proliferation assays
- Cell culture under flow assays
- Hypoxia and oxygen depletion experiments (only ibidi Gas Incubation System CO2/O2 – Silver Line)
Specifications
ibidi Gas Mixer – Silver Line | |
Operating humidity | Max. 80% relative humidity |
Operating temperature | 18–30°C/64–86°F |
Dimensions | 90 x 170 x 230 mm³ |
Weight | 2230 g / 4.9 lbs |
External power supply | AC 100–240 V, 50/60 Hz, 1.4 A |
Humidifying Column | |
Operating humidity | Max. 80% relative humidity |
Dimensions | 70 x 110 x 300 mm³ |
CO2 Control | |
Control range | 0–15% |
Resolution | 0.1% |
Flow Control Mixed Gas | |
Control range | 0–20 l/h |
Humidity Control | |
Control range | 20–99% relative humidity (lower limit is dependent on environment and gas supply, minimum set humidity is 0%) |
Resolution | 0.1% |
Gas Supply (Input) | |
Pressurized air | 1 bar / 14.5 psi optimum (0.4–1.2 bar / 5.8–17.4 psi) |
CO2 | 1 bar / 14.5 psi optimum (0.8–1.2 bar / 11.6–17.4 psi) |
Tubing for all gases (supplied with the system) | PUR/PUN tubing 4 mm inner diameter 6 mm outer diameter 1 mm wall thickness |
Technical Features
- Precise and reliable gas incubation for CO2
- Prevents evaporation inside the Incubation Chamber by active, feedback-controlled humidity regulation (ibidi’s patented Humidity Control)
- Also available with CO2 and O2 control for hypoxia and oxygen depletion experiments: ibidi Gas Incubation System CO2/O2 – Silver Line
- Uses pressurized air to create the gas flow (no vibrations)
- Optional Air Pressure Generator available (for when pressurized air is not obtainable)
- Can be combined with the ibidi Heating System to create a complete Stage Top Incubator for long-term physiologic conditions on the microscope with controlled temperature, humidity, and CO2
- Humidity measurement close to the sample
- Including IncuControl software for instrument control and data recording via a notebook
The Principle of the ibidi Gas Incubation System – Silver Line
Cells react sensitively to changes in their environment. Factors such as temperature, humidity/evaporation, and CO2/O2 levels significantly influence the outcome of cell culture assays. To achieve biologically relevant and reproducible results, it is crucial to maintain optimal conditions on the microscope stage during live cell imaging experiments.
The ibidi Gas Incubation System provides humid and CO2-rich air for stage-top incubators like the ibidi Heating System. It consists of the ibidi Gas Mixer – Silver Line and the Humidifying Column. The gas mixture is continuously flushed through the stage top incubator, ensuring maximum humidity and an optimal pH for bicarbonate-buffered liquids.
For hypoxia assays, the ibidi Gas Incubation System CO2/O2 – Silver Line allows for the precise control of the oxygen levels in your cell culture vessel. The ambient O2 level can be controlled within a range of 1%–21%, and easily adapted to the experimental requirements.
For full control of the incubation environment, ibidi offers Stage Top Incubators, which combine the ibidi Heating System and the ibidi Gas Incubation System, to regulate humidity, temperature, CO2, and (optionally) O2 concentrations.
Preventing Evaporation With ibidi’s Patented Humidity Control
The ratio of dry gas and humidified gas is determined by the actual and preset humidity, and controlled by a feedback mechanism. In a steady-state system (e.g., when both the set and the actual RH are 90%), a mixture of humidified and dry gas enters the ibidi Stage Top Incubator.
Cell behavior is strongly influenced by changes in medium components, such as salts and nutrients. Any evaporation from the cell culture vessels increases the substance concentration in the medium in an undefined way. Therefore, creating ideal humidity conditions—especially during live cell imaging—helps avoid evaporation and leads to reproducible experimental conditions.
The ibidi Gas Incubation System uses the patent-protected ibidi Humidity Control. The unique technology actively humidifies the gas mixture in a fast and reliable way before it enters the stage top incubator. This feedback-controlled mechanism ensures a constant and very high relative humidity (RH) level inside the stage top incubator—identical to the conditions in standard cell culture incubators.
Using the ibidi Humidity Control reliably prevents evaporation in the stage top incubator, which is one of the keys to artifact-free results in live cell imaging.
Find Out More
What Makes the ibidi Humidity Control Special?
Oxygen Depletion / Hypoxia
The oxygen (O2) concentration at normal atmospheric pressure is around 20–21%. However, the O2 levels in healthy body tissues and our blood are much lower. Variations in the oxygen concentration are part of the normal body system, ranging from 14% in the alveoli to 5% in peripheral tissues.
The oxygen levels can be even lower in pathological situations (hypoxia). Hypoxia especially occurs in tumor tissue, which is characterized by markedly low O2 levels that range from approximately 4% to a minimum of below 0.5%.
The ibidi Gas Incubation System CO2/O2 – Silver Line allows for the precise control of oxygen levels in the incubation chamber between 1% to 21%, creating an ideal solution for live cell imaging experiments under hypoxic conditions.
McKeown SR (2014) Defining normoxia, physoxia and hypoxia in tumours-implications for treatment response. Br J Radiol 87(1035):20130676. 10.1259/bjr.20130676.
Read article
O2 partial pressure in several tissue types
(1 kPa ≙ 1 % in gas mix ≙ 7.5 mm Hg).
The Components of the ibidi Gas Incubation System CO2 – Silver Line
ibidi Gas Mixer – Silver LineUnique, patented technology for active humidification of the gas mixture in a fast and reliable wayHumidity can be smoothly adapted to experimental needsUses pressurized air to create the gas flow without vibrationsAvailable as a CO2 and a CO2/O2 version | Humidifying ColumnHumidifies the outgoing CO2 / air mix to prevent sample evaporationHumidification by regulated air flow through the heated water columnHeated column and tube minimize condensation inside the Incubation Chamber | Air Pressure Generator (optional, not included)To be used when pressurized air is not availableReady to use with the ibidi Gas Incubation SystemAvailable for different electric specifications |